Models: 24ACB3, 24ACB7, 24ACC6, 24APA5, 24APA7
When you want a reliable central air conditioner with a great mix of cooling efficiency (up to 18 SEER) and quiet operation (as low as 66 dB), consider these Performance and Comfort series units.
Up to 18 SEER
WeatherArmor™ Protection System
Environmentally-sound Puron® refrigerant
10-year parts limited warranty when properly registered1
Model: 24ACB3 24ACB7 24ACC6 24APA5 24APA7
24ACB3
| Performance | |
| Efficiency | Up to 15 SEER |
| Limited Warranty | 10-year parts limited warranty when properly registered1 |
| ENERGY STAR® | |
| Details | All Carrier air conditioner products achieving system combinations of 14.5 SEER and 12 EER or higher meet the ENERGY STAR guidelines for efficiency. Proper sizing and installation of equipment is critical to achieve optimal performance. Air conditioners must be matched with appropriate indoor coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit the ENERGY STAR website. |
| Sound | |
| Quiet Level2 | As low as 74 dB |
| Features | Sound suppressing compressor blanket |
| Controls | |
| Controls Supported | Edge® and Comfort™ thermostats |
| Technology | |
| Refrigerant | Environmentally-sound Puron® refrigerant |
| Compressor | Single-stage scroll |
| Cooling Capacity (tons) | 1.5 - 5 |
| Pressure Switches | High and Low |
| Aesthetics | |
| Protection | WeatherArmor™ |
| Construction | Galvanized steel |
| Paint | Baked-on, powder coat paint |
| Coil Guard | Steel, louver coil guard |
| ↑ Back to Top | |
24ACB7
| Performance | |
| Efficiency | Up to 18 SEER |
| Limited Warranty | 10-year parts limited warranty when properly registered1 |
| ENERGY STAR® | |
| Details | All Carrier air conditioner products achieving system combinations of 14.5 SEER and 12 EER or higher meet the ENERGY STAR guidelines for efficiency. Proper sizing and installation of equipment is critical to achieve optimal performance. Air conditioners must be matched with appropriate indoor coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit the ENERGY STAR website. |
| Sound | |
| Quiet Level2 | As low as 73 dB |
| Features | Sound suppressing compressor blanket |
| Controls | |
| Controls Supported | Edge® and Comfort™ 2-stage thermostats |
| Technology | |
| Refrigerant | Environmentally-sound Puron® refrigerant |
| Compressor | Two-stage scroll |
| Cooling Capacity (tons) | 2 - 5 |
| Pressure Switches | High and Low |
| Aesthetics | |
| Protection | WeatherArmor™ |
| Construction | Galvanized steel |
| Paint | Baked-on, powder coat paint |
| Coil Guard | Steel, louver Coil Guard |
| ↑ Back to Top | |
24ACC6
| Performance | |
| Efficiency | Up to 16.5 SEER |
| Limited Warranty | 10-year parts limited warranty when properly registered1 |
| ENERGY STAR® | |
| Details | All Carrier air conditioner products achieving system combinations of 14.5 SEER and 12 EER or higher meet the ENERGY STAR guidelines for efficiency. Proper sizing and installation of equipment is critical to achieve optimal performance. Air conditioners must be matched with appropriate indoor coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit the ENERGY STAR website. |
| Sound | |
| Quiet Level2 | As low as 72 dB |
| Features | Sound suppressing compressor blanket |
| Controls | |
| Controls Supported | Edge® and Comfort™ thermostats |
| Technology | |
| Refrigerant | Environmentally-sound Puron® refrigerant |
| Compressor | Single-stage Scroll |
| Cooling Capacity (tons) | 1.5 - 5 |
| Pressure Switches | High and Low |
| Aesthetics | |
| Protection | WeatherArmor™ |
| Construction | Galvanized steel |
| Paint | Baked-on, powder coat paint |
| Coil Guard | Steel, louver Coil Guard |
| ↑ Back to Top | |
24APA5
| Performance | |
| Efficiency | Up to 16.5 SEER |
| Limited Warranty | 10-year parts limited warranty when properly registered1 |
| ENERGY STAR® | |
| Details | All Carrier air conditioner products achieving system combinations of 14.5 SEER and 12 EER or higher meet the ENERGY STAR guidelines for efficiency. Proper sizing and installation of equipment is critical to achieve optimal performance. Air conditioners must be matched with appropriate indoor coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit the ENERGY STAR website. |
| Sound | |
| Quiet Level2 | As low as 66 dB |
| Features | Silencer System II |
| Controls | |
| Controls Supported | Infinity® control, Edge® and Comfort™ thermostats |
| Diagnostic Intelligence | Enhanced diagnostics with Infinity control |
| Technology | |
| Refrigerant | Environmentally-sound Puron® refrigerant |
| Compressor | Single-stage Scroll |
| Cooling Capacity (tons) | 1.5 - 5 |
| Pressure Switches | High and Low |
| Aesthetics | |
| Protection | WeatherArmor™ |
| Construction | Galvanized steel |
| Paint | Baked-on, powder coat paint |
| Coil Guard | Steel, louver Coil Guard |
| ↑ Back to Top | |
24APA7
| Performance | |
| Efficiency | Up to 18 SEER |
| Limited Warranty | 10-year parts limited warranty when properly registered1 |
| ENERGY STAR® | |
| Details | All Carrier air conditioner products achieving system combinations of 14.5 SEER and 12 EER or higher meet the ENERGY STAR guidelines for efficiency. Proper sizing and installation of equipment is critical to achieve optimal performance. Air conditioners must be matched with appropriate indoor coil components to meet ENERGY STAR criteria. Ask your contractor for details or visit the ENERGY STAR website. |
| Sound | |
| Quiet Level2 | As low as 69 dB |
| Features | Silencer System II |
| Controls | |
| Controls Supported | Infinity® control, Edge® and Comfort™ 2-stage thermostats |
| Diagnostic Intelligence | Enhanced diagnostics with Infinity control |
| Technology | |
| Refrigerant | Environmentally-sound Puron® refrigerant |
| Compressor | Two-stage Scroll |
| Cooling Capacity (tons) | 2 - 5 |
| Pressure Switches | High and Low |
| Aesthetics | |
| Protection | WeatherArmor™ |
| Construction | Galvanized steel |
| Paint | Baked-on, powder coat paint |
| Coil Guard | Steel, louver Coil Guard |
| ↑ Back to Top | |
We have recently updated and moved the Carrier site.
Information on this page is no longer being updated.
Click here to be redirected to the new Carrier Home Comfort site.